Development Notes - Network CSTA Log On
From Open CSTA
Using the org.opencsta.tools.blackbox.NetworkBlackBox class, this is how we log in with a Siemens Hipath 3000 series PBX.
54 bytes received Client ---> Server | S: 26 80 33 60 31 a1 7 6 5 2b c 0 81 5a 8a 2 6 80 ac 15 a2 13 a0 11 a0 f 4 6 41 4d 48 4f 53 54 4 5 37 37 37 37 37 be b 28 9 a0 7 a0 5 3 3 0 10 0 77 bytes received Client <--- Server | R: 26 80 4a 61 48 a1 7 6 5 2b c 0 81 5a a2 3 2 1 0 a3 5 a1 3 2 1 0 88 2 6 80 aa 21 a2 1f a0 1d a1 1b 4 10 48 45 36 34 35 50 2e 30 30 2e 30 32 33 3a 36 30 4 7 30 32 33 2e 30 30 30 be a 28 8 a0 6 a0 4 3 2 4 10 17 bytes received Client <--- Server | R: 26 80 e a1 c 2 1 1 2 2 0 d3 30 3 a 1 2 16 bytes received Client ---> Server | S: 26 80 d a2 b 2 1 1 30 6 2 2 0 d3 5 0
We should now be logged into the PBX. This output is for a Siemens Hipath 3000 series system. Use a DataInputStream & DataOutputStream.